IDS 30 F
BETRIEBSANLEITUNG
HEIZSTRAHLER
ORIGINAL INSTRUCTIONS
OIL HEATER
Table of contents
Notes regarding the instructions
Safety
Information about the device
Transport and storage
Assembly and start-up
Operation
Available accessories
Errors and faults
Maintenance
Technical annex
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions via the
following link:
IDS 30 F
https://hub.trotec.com/?id=44289
Disposal
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity of the device or its site of use.
Read all safety warnings and all instructions.Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.Save all warnings and instructions for future
reference.This device must not be used by children and persons
under 16 years of age. Children shall not play with the appliance. Cleaning anduser maintenance shall not be made by children
under 16 years.
Declaration of conformity
Notes regarding the instructions
Symbols
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning of flammable substances
This symbol indicates dangers to the life and health of
persons due to flammable substances.
This symbol indicates dangers to the life and health of
persons due to hot surface.
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or moderate injury.
This signal word indicates important information (e.g. material damage), but does not indicate hazards
Do not use the device in rooms if persons are present
who cannot leave the room independently and who are
not under constant supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
• ground.
Let the device dry out after a wet clean. Do not operate it when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover the device during operation.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible condition. Attention: In Germany, the Federal Emission Protection Directive applies. Do not operate the device for more than 3 months at the same place. Prior to planning the flue gas system, gather information about the national legislation and contact a responsible specialist.• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during operation.Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any defective devices or device parts.Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Neveruse the device if electric cables or the power connection
are damaged!The mains connection must correspond to the
specifications in the Technical annex. Insert the mains plug into a properly fused mains socket.• Observe the device's power input, cable length and
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not place the device on combustible ground.
• Only transport the device in an upright position.
• Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.• Do not store combustible materials near the
device (minimum distance 3 m).
• Do not transport the device whilst the fuel line is
connected. Take the necessary fire protection measures.• Only install the device in roofed outdoor areas or in well-
ventilated indoor spaces with exhaust system.
• Only position the device near flue pipes or electrical supply
control panels that comply with the specified parameters.
• Do not use the heating device together with a
programming device, a timer, a separate remote controlsystem or any other device that automatically switches the
heating device on, as there is a risk of fire if the heating device is covered or incorrectly positioned.
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical overload.
Intended use
The device was developed for the purpose of generating hot air
and may only be used in roofed over outdoor areas or in wellventilated interior spaces whilst adhering to the technical data. The device is suited for heating large rooms such as tents, warehouses, workshops, construction sites, greenhouses or agricultural halls. It is intended to be used without frequent site changes.The device may only be used in rooms with sufficient fresh air
supply and exhaust discharge. The device must only be operated with EL (ultra-light) fuel oil and diesel, however not with petrol, heavy fuel oil etc.The supplied flue pipe may only be used for outdoor
applications.
Foreseeable misuse
• Do not place any objects, e.g. clothing, on the device.
• Do not use this device in the vicinity of fuel, solvents,
varnishes or other easily inflammable vapours or in rooms
where these substances are stored.
• Do not use the device outdoors if it will be exposed to
• adverse weather conditions (e.g. rain) and if roofing is not
available.The device must not be positioned or operated in areas
with a high risk of fires or in potentially explosive
atmospheres.
• Do not use the device out of doors, unless under a roof.
The device must not be operated in rooms with an
• insufficient combustion air supply.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
Personnel qualifications
People who use this device must:• be aware of the dangers resulting from heat, fire hazard
and insufficient ventilation when working with oil heaters.be aware of the dangers that occur when handling fuels
such as EL fuel oil or diesel. have read and understood the instructions, especially the Safety chapter.• Safety devices
The device is equipped with an electronic flame and maximum
temperature monitoring system working with a photo cell and a
safety thermostat. The electronic control unit regulates the start-up, stopping and safety shutdown times in case of malfunctions. The control unit comes with a reset button; its colour (operating display) depends on the operating mode:• indicator light off in pause or standby mode, awaiting the
heating request
continuously green during normal operation of the device
continuously red during a safety shutdown of the device
flashing in orange when the operation was interrupted
owing to great fluctuations in the power supply
(T < 175 V or T > 265 V); automatic resumption when the voltage stabilizes between 190 V and 250 V When the device has triggered a safety shutdown:• Press the reset button (25) for 3 seconds to resume
• operation.
Risk of injury from deflagration!Unburned fuel oil can accumulate in the combustion
chamber and might ignite during the subsequent
restart. Never carry out more than two consecutive restarts.
If the safety shutdown persists:• Determine and eliminate the cause of the fault before
restarting the device (see chapter Errors and faults).
• Press the reset button (25) for at least 5 seconds.
This activates the self-diagnosis programme.Upon completion of the self-diagnosis routine the colour of the
reset button changes to indicate the respectively diagnosed
cause of the fault:• orange flashing indicates that an improperly dimensioned
flame was detected during start-up
red flashing indicates that flame failure was detected
during start-up
flashing that alternates between red and green indicates
that flame failure was detected during operation
continuous orange indicates an internal error of the
electronic controller
• For more information regarding the determination of the cause
of the fault please refer to the chapter Errors and faults
The device is not a toy and does not belong in the
hands of children.
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Improper installation entails a risk of fire. Do not place the device on combustible ground. Do not place the device on high-pile carpets.
The device must not be covered, there is an imminent fire hazard!
Risk of injury due to poisoning!Improper installation of the exhaust system can cause
health problems. Have the system installed by an expert technician!
Behaviour in the event of an emergency
1.
In an emergency, immediately extinguish the pilot flame by setting the selector switch to position 0. In an emergency, disconnect the device from the mains feed-in: Switch the device off and disconnect it from the mains.
2.
• Remove persons from the danger area.
• Do not reconnect a defective device to the mains.
Residual risks
Work on the electrical components must only be
carried out by an authorised specialist company!
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning of flammable substances
Handling fuels entails a risk of fire.Take sufficient precautions when handling fuels such
as fuel oil, kerosene or diesel. Do not spill any diesel, kerosene or fuel oil! Do not inhale the vapours nor swallow any fuel! Avoid skin contact!
Parts of the device, especially at the air outlet, become very hot during operation. There is a danger of burning and fire. Do not touch the device during operation!During operation observe a safety distance of at least 3
m to the device front! Observe the minimum distancefrom walls or other objects according to the technical
data!
Parts of this appliance can become very hot and cause
burns. Particular attention is to be paid when there are children or vulnerable persons present!
Improper handling entails a risk of burning. Only use the device as intended!
Improper handling entails a risk of burning and electric
shock. Only use the device as intended!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Information about the device
Device description
The indirectly fired oil heater serves the purpose of heating the
room air so as to quickly heat large, well-ventilated rooms. The oil heater runs on fuel oil or diesel, it must not be used with petrol, heavy fuel oil etc.It is an oil heater with indirect combustion to be installed in
roofed outdoor areas or in rooms with a sufficient fresh air
supply. Since it is not equipped with an integrated tank, it is ideally suited for mobile applications and frequently changing locations.The device is equipped with an exhaust gas connection for the
discharge of exhaust gases via the flue. It is refuelled externally using a tank or jerrycan.The selection option between two operating modes permits both
a manual regulation of the oil heater by the user and an
automatic control aided by an external thermostat.
Functional principle
The device generates warmth by conveying the sucked-in, cold air past a combustion chamber. Inside the combustion chamber the fuel is burned. The sucked-in air is heated and fed back to the environment via the air outlet.
Device depiction
Rain cap
Flue pipe
Housing
Transport handle
Frame
Tank line connection
Filler neck retainer
Control panel
Air inlet
Connection set for jerrycan (optional)
Protective bar
Air outlet
Flue pipe connection for flue gas evacuation
12345131211ONON1067984
Schematic inside view
Transport and storage
If you store or transport the device improperly, the device may be damaged.Note the information regarding transport and storage of
the device.
Transport
Before transporting the device, observe the following:• Hold onto the mains plug while pulling the power cable out
Switch the device off.
of the mains socket.
• Do not use the power cable to drag the device.
Allow the device to cool down sufficiently.• Loosen the quick couplings at the tank connection.
• When using the optional jerrycan adapter:
– Remove the nozzle for refuelling from the jerrycan. – Insert the filler neck in the retainer. – Close the fastener.
Combustion chamber
Burner
Nozzle
Magnet valve
Motor
Fan
Pump
Control panel
Selector switch:• l = ON (activate manual operation)
• 0 = switch the device off
l = ON (activate automatic operation)
Thermostat socket
Lamp
Power cable
Reset button
Before transporting the device, disassemble the flue pipe and put it into the designated holding fixture. Proceed as follows to disassemble the flue pipe:• Remove the rain cap (1) from the flue pipe.
• Remove the flue pipe (2) from the flue pipe connection.
• Put the flue pipe into the holding fixture at the device.
• Attach the rain cap (1) to the flue pipe connection (13).
161417151819202223242521ONON
• Check the flue pipe for tight fit.
Storage
Before storing the device, proceed as follows:• Hold onto the mains plug while pulling the power cable out
Switch off the device.
of the mains socket. Allow the device to cool down sufficiently. Loosen the quick couplings at the tank connection.• When using the optional jerrycan adapter:
– Remove the nozzle for refuelling from the jerrycan. – Insert the filler neck in the retainer. – Close the fastener.
While transporting the device, observe the following:• Always utilize the help of another person to transport the
device. Use the transport handles.Please note that the protective bars are not fit to be used
as transport handles.• When the device is not being used, observe the following
storage conditions:• dry and protected from frost and heat
in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
up to 2 devices may be stacked on top of one another for• storage purposes
1213ONON
Assembly and start-up
Scope of delivery
1 x Device• 1 x Filler neck retainer
• 1 x Frame attachment
• 1 x Rain cap
• 1 x Exhaust duct extension
• 1 x Flue pipe
• 1 x Manual
• Unpacking the device
• Open the cardboard box and take the device out.
• Completely remove the packaging.
• Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Assembly
Mounting the transport frame
Upon delivery the transport frame is already partially
preassembled. The protective bars at the front and rear are still to be mounted.• Attach the first protective bar at the front of the device.
• Affix the rear protective bar using 2 screws on each side.
• Check the protective bars for tight fit.
• Tighten the screws on both sides.
Flue gas evacuation
• Prior to planning the flue gas system, gather information
about the national legislation and contact a responsible
specialist (cf. DIN in Germany).Ensure an unimpeded and sufficient combustion air supply
(e.g. by means of ventilation openings in doors, ceilings, windows, walls or via interconnected airways).• Have the exhaust emission of the burner checked at
• regular intervals.
ONONONON1213
Mounting the flue pipe
The flue pipe may only be used for outdoor flue gas evacuation
applications. Proceed as follows to attach the flue pipe to the device:• Remove the flue pipe (2) from the holding fixture.
• Detach the rain cap (1) from the flue pipe connection (13).
• Put the rain cap (1) onto the flue pipe (2).
• Check the flue pipe for tight fit.
• Connect the flue pipe (2) to the flue pipe connection (13) of
the device
1213ONON21312
Flue duct
The following schematic representation should be considered
when planning a flue duct:
Wall duct
The following schematic representation should be considered
when planning a wall duct:
Flue pipe connection
Cleaning opening with explosion protection flap
Outer wall
Flue – inside min. 20 x 20 cm
29 Wall duct with elbow min. 5°
Dimensions: A: min. 1 m• B: min. 1 m
• C: as short as possible
Flue pipe connection
Outer wall
29 Wall duct with elbow min. 5°Draught booster H-shaped
Dimensions: A: min. 1 m• B: min. 1 m
• C: as short as possible
• E: min. 1 m
Establishing the oil supply
Quick couplings are used to connect the device to an external
tank or the optional jerrycan. ü Switch the device off according to the Shutdown chapter. ü Before attempting to connect the external tank, wait until
the device has cooled down completely.
ü Only use fuel suitable for the device (see technical data).• Position the device on firm, level and incombustible
ground.
• Unscrew the cover from the tank connection of the
external tank.
• Unscrew the cover of the device from the tank connection
of the device.
• Attach the feed and return hose to the tank connection of
the external tank using the quick couplings.
• Attach the feed and return hose to the tank connection of
the device using the quick couplings.
• Make sure that the hose is firmly attached to avoid
leakage.
• The device is now connected to the oil supply.
Positioning
A number of spatial and technical conditions have to be
considered for the selection of the device's installation site.Non-observance may impair the proper functioning of the device
or the accessories or can entail risks of personal injury and
property damage. The following is to be observed for positioning:• The device may only be operated on roofed over surfaces.
The device is to be set up in a stable position on
incombustible ground. The device must be set up in close proximity to a flue, an outer wall or on an open, ventilated surface.The device must be connected to a properly secured mains
power socket.The room where the device is positioned must be
sufficiently ventilated. Ensure a sufficient fresh air supply, especially when there are people or animals in the same room with the device!The minimum distance between the wall and the air inlet
opening of the device must be at least 2 m (see figure).The minimum distance between the device and
combustible materials must be at least 3 m. The inlet and outlet openings must not be covered. There must be no walls or large objects near the device.There must be a sufficient number of fire extinguishers
available
ONON
Start-up
• Check the scope of delivery of your device for
completeness. If an accessory part is missing, pleasecontact the Trotec customer service or the specialist dealer
where you purchased the device.Check the device and its connection parts for potential
damage.• Observe the conditions described in the chapter
• Positioning.
Install the exhaust system of the device in a technically
correct manner. You can also connect the device to a flue or an outer wall as illustrated in chapter Assembly.Connect the device to an external tank or jerrycan as
described in the chapter Establishing the oil supply.Check the device for its proper condition prior to start-up
and at regular intervals during application.Check whether the characteristics of the power grid
conform to those on the nameplate.Each time before you plug the mains plug into the mains
socket and switch on the device, make sure that the fan is moving freely.Connect the mains cable to a properly secured
socket (230 V / 50 Hz / 10 A). On construction sites, there must be a residual current device (RCD) upstream of the socket in accordance with national regulations (in Germany: VDE 0100/0105). The device is now ready for operation.• Operation
The device may only be used by accordingly instructed persons.
Operating elements
Fire hazard if device is covered or due to incorrect
positioning of the device!There is a risk of fire if the heating device is covered or
incorrectly positioned.Never cover the device during operation and position it
with sufficient distance to walls and objects (according to the chapter Technical annex).
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Selector switch:• l = ON (activate manual operation)
• 0 = switch the device off
l = ON (activate automatic operation)
Thermostat socket
Lamp
Power cable
Reset button
The device has two operating modes:• Manual operation
• Automatic operation with external thermostat (optional)
Manual operation
For continuous heat generation, here, the device operates independently of a control unit.• Switch the device on by setting the position of the selector
switch (21) to position I (activate manual operation).
Automatic operation (optional)Automatic operation of the device is only an option with a
connected controller (optional), e.g. a thermostat. The thermostat is connected to the thermostat socket (22).• Switch the device on by setting the position of the selector
switch (21) to II (activate automatic operation). To confirm the completion of the start-up process, the
electronic control unit causes the reset button (25) to briefly flash in red.
Shutdown
Disconnecting the oil supply
Proceed as follows to disconnect the oil supply:ü Make sure that there is no fuel residue in the feed and
return hose.
ü Switch the device off according to the Shutdown chapter. ü Before attempting to connect the external tank, wait until
the device has cooled down completely.
• Disconnect the feed and return hose from the tank
connection of the external tank using the quick couplings.
• Disconnect the feed and return hose from the tank
connection of the device IDS 30 F using the quick couplings.
• Screw the cover of the external tank back onto the tank
connection.
• Screw the suitable cover onto the tank connection of the
device IDS 30 F.
Work on the electrical components must only be
carried out by an authorised specialist company!
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Damage to the device due to overheating! Never switch off the device by pulling the mains plug. This may lead to overheating! Switch off the device properly. Only pull the mains plug once the fan motor has stopped completely.• Switch off the device by setting the selector switch to
2.
position 0. If you use a thermostat, switch off the device using the settings of the controller (e.g. by setting a lower temperature at the thermostat).The flame goes out and the fan continues to run for
approx. 90 seconds in order to cool down the burner.
• Wait until the automatic after-cooling is completed.
• Secure the device against inadvertent switch-on by pulling
the mains plug.
Restarting the device after a malfunction
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be insufficient. In this case, the flame monitoring system will respond and the device will be blocked.• Wait for approx. 1 minute.
• Press the reset button (25) for approx. 5 seconds.
• Switch the device on.
If the device still does not start:• Make sure that the device is properly connected to an
external tank or a jerrycan (see chapter Assembly). Press the reset button.
• To detect further causes of error, see chapter Errors and faults
ONON
Available accessories
Errors and faults
Accessories
Thermostat with 10 m cable
Connection kit for external oil tank
Adapter set tank kit – oil hose
Article number
6.100.007.016
6.100.006.185
7.210.000.003
Tank line with quick couplings, length 5 m 6.100.006.037
Connection set for external jerrycan
Tank liquid level indication
Filler neck oil filter
6.100.006.184
6.100.006.160
6.100.006.161
90° arc connection for exhaust gas pipe
6.100.006.216
Air hose Tronect SP-C, length 7.6 m
6.100.001.265
Only use accessories and additional equipment
specified in the instructions.Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Risk of injury due to improper repair!Never try to make any modifications or repairs on the
device.Unauthorised modifications can lead to serious injuries
or death.Have a certified specialist workshop perform the repair
work.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:• Check the power connection.
Check the power cable and mains plug for damage. If you notice damages, do not try to take the device back into operation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Check the on-site fusing.
• Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks: Please contact the customer service. If necessary, bring thedevice to an authorised specialist electrical company or to
Trotec for repair.
Error codes
Error / fault
Fan does not start
and flame does not
ignite
Fan does not start
or switches off
during start-up or
operation
Operation indicator
Off
Self-diagnosis
Cause
• Controller set incorrectly
Controller faulty
Orange flashing
• No power supply
Voltage < 175 V
Voltage > 265 V
Fan switches off
during start-up or
operation
Continuous red
Orange flashing
Flame present prior to ignition of
the transformer
Photo cell faulty
Remedy
Check if the controller is set correctly (e.g.the temperature set at the thermostat must
be higher than the room temperature).
Have the controller replaced by the customer
service.
Check the characteristics of the electrical
system (230 V-1~ – 50 Hz).Check the functionality and position of the
selector switch. Check the fuse for soundness.
Check the supply voltage. The device willrestart automatically when the voltage value
exceeds 190 V.
Check the supply voltage. The device willrestart automatically when the voltage value
falls below 250 V.
Instruct the customer service to have the
device cleaned and fuel oil residues
removed from the combustion chamber.
Have the photo cell exchanged by the
Red flashing or
flashing that
alternates between
red and green
Motor winding interrupted or
blown
Have the motor replaced by the customer
service.
Motor bearing blocked
Motor capacitor blown
No ignition
Flame monitoring system faulty
Photo cell faulty
Have the motor replaced by the customer
service.
Have the motor capacitor replaced by the
Check the connections of the ignition cables
at the electrodes and the transformer.Check the position and the distance of the
electrodes. Check whether the electrodes are clean.Have the transformer replaced by the
Have the flame monitoring system replaced
by the customer service.
Have the photo cell exchanged by the
customer service
Burner is supplied with no or
insufficient fuel oil
Magnet valve faulty
Continuous orange
Internal error of the electronic
control unit
Fan starts and flame
burns with smoke
formation
Continuous green
• Insufficient supply of combustion
air
Excessive supply of combustion
air
• to have the coupling between the
pump and the motor checked for
soundness.• to have the fuel oil circuit checked for
intruded air and to have the lines and
filter seal checked for tightness.
to have the nozzle cleaned or
exchanged.
• to have the electrical connections
checked.• to have the safety thermostat LI
checked.
to have the magnet valve cleaned or
exchanged.
Instruct the customer service to have the
control unit reset; try at least twice. If the problem persists, have the control unit replaced.
Remove all obstacles and obstructions from
the inlet and/or outlet openings.Have the position of the adjustment ring for
the regulation of the air supply checked by
the customer service.Have the supporting disc of the burner
checked by the customer service.
Have the position of the adjustment ring for
the regulation of the air supply checked by
the customer service.
Used fuel oil contaminated or
contains water
Replace used fuel oil with clean fuel oil. Clean the fuel oil filter.
Air inside the fuel oil circuit
Insufficient fuel oil quantity at the
burner
Excessive amount of fuel oil at
the burner
Have the lines and the fuel oil filter checked
for tightness by the customer service.
• to have the pump pressure checked.
• to have the nozzle cleaned or replaced
• to have the nozzle replaced.
Device does not
switch off
Continuous green
• Sealing of the magnet valve
faulty
Have the magnet valve replaced by the
Maintenance
Maintenance and care interval
Check air inlets and outlets for dirt
and foreign objects and clean
Check air inlet grid(s) for dirt andforeign objects and clean
Clean the exterior
Visually check the inside of the
device for dirt
Check for damage
Check attachment screws
Test run
Maintenance intervals
before every
start-up
as needed
at least every
2 weeks
at least every
4 weeks
at least every
6 months
at least
annually
Maintenance and care log
Device type:
Device number
Maintenance and care interval
Check air inlets and outlets for dirt
and foreign objects and clean
Check air inlet grid(s) for dirt andforeign objects and clean
Clean the exterior
Visually check the inside of the
device for dirt
Check for damage
Check attachment screws
Test run
Comments
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature
Activities required before starting maintenance
Technical annex
Do not touch the mains plug with wet or damp hands.
Switch the device off.• Hold onto the mains plug while pulling the power cable out
of the mains socket. Allow the device to cool down completely.
• Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. Wipe the housing dry after cleaning.
Technical data
Parameter
Article number
Method of heating
Air flow rate
Fan
Max. nominal heat input
Nominal heat output
Value
1.430.000.128
indirect
m³/h
axial fan
34.1 kW
28.8 kW (24764 kcal)
Temperature increase ΔT
70 °C
Input voltage
Current consumption
Air transport hose connection Ø
Flue pipe connection Ø
Max. fuel consumption
V / 50 Hz
1.56 A
300 mm
150 mm
3.25 l/h
Sound level (at a distance of 1m)
75 dB (A)
Dimensions (length x width x height)
Minimum distance to walls and other
objects
A: top B: rear C: side D: front
56 kg
Weight
Fuels
The following fuels are approved for the device:• Diesel
EL fuel oil
Wiring diagram
Abbreviation
Component
Abbreviation
Component
AP
TA
ST
LI 1
EV 1
Control unit
Thermostat connection
Indicator light
Safety thermostat
Magnet valve
FO
CO
FUA
RV
Photo cell
Condenser
Fan motor
Fusing 3.15 A
Selector switch
Overview of spare parts and spare parts list IDS 30 F
Info
The position numbers of the spare parts differ from
those describing the positions of the components
mentioned in these instructions.
Cylinder head screw
(DIN 912 –M 8 x 25 VA)
Washer (DIN 125 – A Ø8.4 VA)
Self-locking hexagon nut
(DIN 985 – M 8 VA)
Washer
(DIN – Ø8.4xØ24x1.8 VA)
Self-locking hexagon nut
(DIN 985 – M 6)
Oil heater
Rivet (Ø4x10 Al)
Pipe holding fixture
Hose connection (IDS30 accessory, 300 mm adapter)
Universal connection (DN 150, conical) Rain cap (DN 150) Rivet (Ø3.2x8 V2A)
Washer (DIN – Ø6.4xØ20x1.25) 11
Bungee cord (l=450 mm) IDS 30 F frame
Hexagon socket countersunk screw
Info
The position numbers of the spare parts differ from
those describing the positions of the components
mentioned in these instructions.
Outlet cone
Flue pipe connection
Insulation plate
Combustion chamber
Top section of the body
Bottom section of the body
Support bracket body
Motor
Condenser
Support bracket engine
Power cable retainer
Cable feed-through
Air collector
Fan
Retaining clip
Air inlet grid
Flexible fuel oil hose
Clamping piece
Filter
Flexible fuel oil hose
Control box
Switchboard cover
Cable feed-through
Burner tube
Safety thermostat
Support bracket thermostat
Control box panel
Flame monitoring device
51 Mounting plate
Double-pole switch
Socket
Thermostat socket cover
Power supply cable
Lamp
Fuel oil pump
Solenoid valve coil
Solenoid valve housing
Connector, Fe
Engine / pump coupling
Connector, Fe
Fine hose
Nozzle
Nozzle holder
Supporting disc burner
Lock nut, brass
Ignition electrode
High-voltage cable
Photo cell
LDR retainer
Lock-out switch protection
BETRIEBSANLEITUNG
HEIZSTRAHLER
ORIGINAL INSTRUCTIONS
OIL HEATER
Table of contents
Notes regarding the instructions
Safety
Information about the device
Transport and storage
Assembly and start-up
Operation
Available accessories
Errors and faults
Maintenance
Technical annex
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions via the
following link:
IDS 30 F
https://hub.trotec.com/?id=44289
Disposal
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity of the device or its site of use.
Read all safety warnings and all instructions.Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.Save all warnings and instructions for future
reference.This device must not be used by children and persons
under 16 years of age. Children shall not play with the appliance. Cleaning anduser maintenance shall not be made by children
under 16 years.
Declaration of conformity
Notes regarding the instructions
Symbols
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning of flammable substances
This symbol indicates dangers to the life and health of
persons due to flammable substances.
This symbol indicates dangers to the life and health of
persons due to hot surface.
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or moderate injury.
This signal word indicates important information (e.g. material damage), but does not indicate hazards
Do not use the device in rooms if persons are present
who cannot leave the room independently and who are
not under constant supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
• ground.
Let the device dry out after a wet clean. Do not operate it when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover the device during operation.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible condition. Attention: In Germany, the Federal Emission Protection Directive applies. Do not operate the device for more than 3 months at the same place. Prior to planning the flue gas system, gather information about the national legislation and contact a responsible specialist.• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during operation.Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any defective devices or device parts.Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Neveruse the device if electric cables or the power connection
are damaged!The mains connection must correspond to the
specifications in the Technical annex. Insert the mains plug into a properly fused mains socket.• Observe the device's power input, cable length and
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not place the device on combustible ground.
• Only transport the device in an upright position.
• Only use original spare parts, for otherwise safe and
functional operation cannot be ensured.• Do not store combustible materials near the
device (minimum distance 3 m).
• Do not transport the device whilst the fuel line is
connected. Take the necessary fire protection measures.• Only install the device in roofed outdoor areas or in well-
ventilated indoor spaces with exhaust system.
• Only position the device near flue pipes or electrical supply
control panels that comply with the specified parameters.
• Do not use the heating device together with a
programming device, a timer, a separate remote controlsystem or any other device that automatically switches the
heating device on, as there is a risk of fire if the heating device is covered or incorrectly positioned.
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical overload.
Intended use
The device was developed for the purpose of generating hot air
and may only be used in roofed over outdoor areas or in wellventilated interior spaces whilst adhering to the technical data. The device is suited for heating large rooms such as tents, warehouses, workshops, construction sites, greenhouses or agricultural halls. It is intended to be used without frequent site changes.The device may only be used in rooms with sufficient fresh air
supply and exhaust discharge. The device must only be operated with EL (ultra-light) fuel oil and diesel, however not with petrol, heavy fuel oil etc.The supplied flue pipe may only be used for outdoor
applications.
Foreseeable misuse
• Do not place any objects, e.g. clothing, on the device.
• Do not use this device in the vicinity of fuel, solvents,
varnishes or other easily inflammable vapours or in rooms
where these substances are stored.
• Do not use the device outdoors if it will be exposed to
• adverse weather conditions (e.g. rain) and if roofing is not
available.The device must not be positioned or operated in areas
with a high risk of fires or in potentially explosive
atmospheres.
• Do not use the device out of doors, unless under a roof.
The device must not be operated in rooms with an
• insufficient combustion air supply.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
Personnel qualifications
People who use this device must:• be aware of the dangers resulting from heat, fire hazard
and insufficient ventilation when working with oil heaters.be aware of the dangers that occur when handling fuels
such as EL fuel oil or diesel. have read and understood the instructions, especially the Safety chapter.• Safety devices
The device is equipped with an electronic flame and maximum
temperature monitoring system working with a photo cell and a
safety thermostat. The electronic control unit regulates the start-up, stopping and safety shutdown times in case of malfunctions. The control unit comes with a reset button; its colour (operating display) depends on the operating mode:• indicator light off in pause or standby mode, awaiting the
heating request
continuously green during normal operation of the device
continuously red during a safety shutdown of the device
flashing in orange when the operation was interrupted
owing to great fluctuations in the power supply
(T < 175 V or T > 265 V); automatic resumption when the voltage stabilizes between 190 V and 250 V When the device has triggered a safety shutdown:• Press the reset button (25) for 3 seconds to resume
• operation.
Risk of injury from deflagration!Unburned fuel oil can accumulate in the combustion
chamber and might ignite during the subsequent
restart. Never carry out more than two consecutive restarts.
If the safety shutdown persists:• Determine and eliminate the cause of the fault before
restarting the device (see chapter Errors and faults).
• Press the reset button (25) for at least 5 seconds.
This activates the self-diagnosis programme.Upon completion of the self-diagnosis routine the colour of the
reset button changes to indicate the respectively diagnosed
cause of the fault:• orange flashing indicates that an improperly dimensioned
flame was detected during start-up
red flashing indicates that flame failure was detected
during start-up
flashing that alternates between red and green indicates
that flame failure was detected during operation
continuous orange indicates an internal error of the
electronic controller
• For more information regarding the determination of the cause
of the fault please refer to the chapter Errors and faults
The device is not a toy and does not belong in the
hands of children.
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Improper installation entails a risk of fire. Do not place the device on combustible ground. Do not place the device on high-pile carpets.
The device must not be covered, there is an imminent fire hazard!
Risk of injury due to poisoning!Improper installation of the exhaust system can cause
health problems. Have the system installed by an expert technician!
Behaviour in the event of an emergency
1.
In an emergency, immediately extinguish the pilot flame by setting the selector switch to position 0. In an emergency, disconnect the device from the mains feed-in: Switch the device off and disconnect it from the mains.
2.
• Remove persons from the danger area.
• Do not reconnect a defective device to the mains.
Residual risks
Work on the electrical components must only be
carried out by an authorised specialist company!
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning of flammable substances
Handling fuels entails a risk of fire.Take sufficient precautions when handling fuels such
as fuel oil, kerosene or diesel. Do not spill any diesel, kerosene or fuel oil! Do not inhale the vapours nor swallow any fuel! Avoid skin contact!
Parts of the device, especially at the air outlet, become very hot during operation. There is a danger of burning and fire. Do not touch the device during operation!During operation observe a safety distance of at least 3
m to the device front! Observe the minimum distancefrom walls or other objects according to the technical
data!
Parts of this appliance can become very hot and cause
burns. Particular attention is to be paid when there are children or vulnerable persons present!
Improper handling entails a risk of burning. Only use the device as intended!
Improper handling entails a risk of burning and electric
shock. Only use the device as intended!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Information about the device
Device description
The indirectly fired oil heater serves the purpose of heating the
room air so as to quickly heat large, well-ventilated rooms. The oil heater runs on fuel oil or diesel, it must not be used with petrol, heavy fuel oil etc.It is an oil heater with indirect combustion to be installed in
roofed outdoor areas or in rooms with a sufficient fresh air
supply. Since it is not equipped with an integrated tank, it is ideally suited for mobile applications and frequently changing locations.The device is equipped with an exhaust gas connection for the
discharge of exhaust gases via the flue. It is refuelled externally using a tank or jerrycan.The selection option between two operating modes permits both
a manual regulation of the oil heater by the user and an
automatic control aided by an external thermostat.
Functional principle
The device generates warmth by conveying the sucked-in, cold air past a combustion chamber. Inside the combustion chamber the fuel is burned. The sucked-in air is heated and fed back to the environment via the air outlet.
Device depiction
Rain cap
Flue pipe
Housing
Transport handle
Frame
Tank line connection
Filler neck retainer
Control panel
Air inlet
Connection set for jerrycan (optional)
Protective bar
Air outlet
Flue pipe connection for flue gas evacuation
12345131211ONON1067984
Schematic inside view
Transport and storage
If you store or transport the device improperly, the device may be damaged.Note the information regarding transport and storage of
the device.
Transport
Before transporting the device, observe the following:• Hold onto the mains plug while pulling the power cable out
Switch the device off.
of the mains socket.
• Do not use the power cable to drag the device.
Allow the device to cool down sufficiently.• Loosen the quick couplings at the tank connection.
• When using the optional jerrycan adapter:
– Remove the nozzle for refuelling from the jerrycan. – Insert the filler neck in the retainer. – Close the fastener.
Combustion chamber
Burner
Nozzle
Magnet valve
Motor
Fan
Pump
Control panel
Selector switch:• l = ON (activate manual operation)
• 0 = switch the device off
l = ON (activate automatic operation)
Thermostat socket
Lamp
Power cable
Reset button
Before transporting the device, disassemble the flue pipe and put it into the designated holding fixture. Proceed as follows to disassemble the flue pipe:• Remove the rain cap (1) from the flue pipe.
• Remove the flue pipe (2) from the flue pipe connection.
• Put the flue pipe into the holding fixture at the device.
• Attach the rain cap (1) to the flue pipe connection (13).
161417151819202223242521ONON
• Check the flue pipe for tight fit.
Storage
Before storing the device, proceed as follows:• Hold onto the mains plug while pulling the power cable out
Switch off the device.
of the mains socket. Allow the device to cool down sufficiently. Loosen the quick couplings at the tank connection.• When using the optional jerrycan adapter:
– Remove the nozzle for refuelling from the jerrycan. – Insert the filler neck in the retainer. – Close the fastener.
While transporting the device, observe the following:• Always utilize the help of another person to transport the
device. Use the transport handles.Please note that the protective bars are not fit to be used
as transport handles.• When the device is not being used, observe the following
storage conditions:• dry and protected from frost and heat
in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
up to 2 devices may be stacked on top of one another for• storage purposes
1213ONON
Assembly and start-up
Scope of delivery
1 x Device• 1 x Filler neck retainer
• 1 x Frame attachment
• 1 x Rain cap
• 1 x Exhaust duct extension
• 1 x Flue pipe
• 1 x Manual
• Unpacking the device
• Open the cardboard box and take the device out.
• Completely remove the packaging.
• Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Assembly
Mounting the transport frame
Upon delivery the transport frame is already partially
preassembled. The protective bars at the front and rear are still to be mounted.• Attach the first protective bar at the front of the device.
• Affix the rear protective bar using 2 screws on each side.
• Check the protective bars for tight fit.
• Tighten the screws on both sides.
Flue gas evacuation
• Prior to planning the flue gas system, gather information
about the national legislation and contact a responsible
specialist (cf. DIN in Germany).Ensure an unimpeded and sufficient combustion air supply
(e.g. by means of ventilation openings in doors, ceilings, windows, walls or via interconnected airways).• Have the exhaust emission of the burner checked at
• regular intervals.
ONONONON1213
Mounting the flue pipe
The flue pipe may only be used for outdoor flue gas evacuation
applications. Proceed as follows to attach the flue pipe to the device:• Remove the flue pipe (2) from the holding fixture.
• Detach the rain cap (1) from the flue pipe connection (13).
• Put the rain cap (1) onto the flue pipe (2).
• Check the flue pipe for tight fit.
• Connect the flue pipe (2) to the flue pipe connection (13) of
the device
1213ONON21312
Flue duct
The following schematic representation should be considered
when planning a flue duct:
Wall duct
The following schematic representation should be considered
when planning a wall duct:
Flue pipe connection
Cleaning opening with explosion protection flap
Outer wall
Flue – inside min. 20 x 20 cm
29 Wall duct with elbow min. 5°
Dimensions: A: min. 1 m• B: min. 1 m
• C: as short as possible
Flue pipe connection
Outer wall
29 Wall duct with elbow min. 5°Draught booster H-shaped
Dimensions: A: min. 1 m• B: min. 1 m
• C: as short as possible
• E: min. 1 m
Establishing the oil supply
Quick couplings are used to connect the device to an external
tank or the optional jerrycan. ü Switch the device off according to the Shutdown chapter. ü Before attempting to connect the external tank, wait until
the device has cooled down completely.
ü Only use fuel suitable for the device (see technical data).• Position the device on firm, level and incombustible
ground.
• Unscrew the cover from the tank connection of the
external tank.
• Unscrew the cover of the device from the tank connection
of the device.
• Attach the feed and return hose to the tank connection of
the external tank using the quick couplings.
• Attach the feed and return hose to the tank connection of
the device using the quick couplings.
• Make sure that the hose is firmly attached to avoid
leakage.
• The device is now connected to the oil supply.
Positioning
A number of spatial and technical conditions have to be
considered for the selection of the device's installation site.Non-observance may impair the proper functioning of the device
or the accessories or can entail risks of personal injury and
property damage. The following is to be observed for positioning:• The device may only be operated on roofed over surfaces.
The device is to be set up in a stable position on
incombustible ground. The device must be set up in close proximity to a flue, an outer wall or on an open, ventilated surface.The device must be connected to a properly secured mains
power socket.The room where the device is positioned must be
sufficiently ventilated. Ensure a sufficient fresh air supply, especially when there are people or animals in the same room with the device!The minimum distance between the wall and the air inlet
opening of the device must be at least 2 m (see figure).The minimum distance between the device and
combustible materials must be at least 3 m. The inlet and outlet openings must not be covered. There must be no walls or large objects near the device.There must be a sufficient number of fire extinguishers
available
ONON
Start-up
• Check the scope of delivery of your device for
completeness. If an accessory part is missing, pleasecontact the Trotec customer service or the specialist dealer
where you purchased the device.Check the device and its connection parts for potential
damage.• Observe the conditions described in the chapter
• Positioning.
Install the exhaust system of the device in a technically
correct manner. You can also connect the device to a flue or an outer wall as illustrated in chapter Assembly.Connect the device to an external tank or jerrycan as
described in the chapter Establishing the oil supply.Check the device for its proper condition prior to start-up
and at regular intervals during application.Check whether the characteristics of the power grid
conform to those on the nameplate.Each time before you plug the mains plug into the mains
socket and switch on the device, make sure that the fan is moving freely.Connect the mains cable to a properly secured
socket (230 V / 50 Hz / 10 A). On construction sites, there must be a residual current device (RCD) upstream of the socket in accordance with national regulations (in Germany: VDE 0100/0105). The device is now ready for operation.• Operation
The device may only be used by accordingly instructed persons.
Operating elements
Fire hazard if device is covered or due to incorrect
positioning of the device!There is a risk of fire if the heating device is covered or
incorrectly positioned.Never cover the device during operation and position it
with sufficient distance to walls and objects (according to the chapter Technical annex).
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Selector switch:• l = ON (activate manual operation)
• 0 = switch the device off
l = ON (activate automatic operation)
Thermostat socket
Lamp
Power cable
Reset button
The device has two operating modes:• Manual operation
• Automatic operation with external thermostat (optional)
Manual operation
For continuous heat generation, here, the device operates independently of a control unit.• Switch the device on by setting the position of the selector
switch (21) to position I (activate manual operation).
Automatic operation (optional)Automatic operation of the device is only an option with a
connected controller (optional), e.g. a thermostat. The thermostat is connected to the thermostat socket (22).• Switch the device on by setting the position of the selector
switch (21) to II (activate automatic operation). To confirm the completion of the start-up process, the
electronic control unit causes the reset button (25) to briefly flash in red.
Shutdown
Disconnecting the oil supply
Proceed as follows to disconnect the oil supply:ü Make sure that there is no fuel residue in the feed and
return hose.
ü Switch the device off according to the Shutdown chapter. ü Before attempting to connect the external tank, wait until
the device has cooled down completely.
• Disconnect the feed and return hose from the tank
connection of the external tank using the quick couplings.
• Disconnect the feed and return hose from the tank
connection of the device IDS 30 F using the quick couplings.
• Screw the cover of the external tank back onto the tank
connection.
• Screw the suitable cover onto the tank connection of the
device IDS 30 F.
Work on the electrical components must only be
carried out by an authorised specialist company!
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands.Hold onto the mains plug while pulling the power cable
out of the mains socket.
Damage to the device due to overheating! Never switch off the device by pulling the mains plug. This may lead to overheating! Switch off the device properly. Only pull the mains plug once the fan motor has stopped completely.• Switch off the device by setting the selector switch to
2.
position 0. If you use a thermostat, switch off the device using the settings of the controller (e.g. by setting a lower temperature at the thermostat).The flame goes out and the fan continues to run for
approx. 90 seconds in order to cool down the burner.
• Wait until the automatic after-cooling is completed.
• Secure the device against inadvertent switch-on by pulling
the mains plug.
Restarting the device after a malfunction
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be insufficient. In this case, the flame monitoring system will respond and the device will be blocked.• Wait for approx. 1 minute.
• Press the reset button (25) for approx. 5 seconds.
• Switch the device on.
If the device still does not start:• Make sure that the device is properly connected to an
external tank or a jerrycan (see chapter Assembly). Press the reset button.
• To detect further causes of error, see chapter Errors and faults
ONON
Available accessories
Errors and faults
Accessories
Thermostat with 10 m cable
Connection kit for external oil tank
Adapter set tank kit – oil hose
Article number
6.100.007.016
6.100.006.185
7.210.000.003
Tank line with quick couplings, length 5 m 6.100.006.037
Connection set for external jerrycan
Tank liquid level indication
Filler neck oil filter
6.100.006.184
6.100.006.160
6.100.006.161
90° arc connection for exhaust gas pipe
6.100.006.216
Air hose Tronect SP-C, length 7.6 m
6.100.001.265
Only use accessories and additional equipment
specified in the instructions.Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Risk of injury due to improper repair!Never try to make any modifications or repairs on the
device.Unauthorised modifications can lead to serious injuries
or death.Have a certified specialist workshop perform the repair
work.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:• Check the power connection.
Check the power cable and mains plug for damage. If you notice damages, do not try to take the device back into operation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Check the on-site fusing.
• Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks: Please contact the customer service. If necessary, bring thedevice to an authorised specialist electrical company or to
Trotec for repair.
Error codes
Error / fault
Fan does not start
and flame does not
ignite
Fan does not start
or switches off
during start-up or
operation
Operation indicator
Off
Self-diagnosis
Cause
• Controller set incorrectly
Controller faulty
Orange flashing
• No power supply
Voltage < 175 V
Voltage > 265 V
Fan switches off
during start-up or
operation
Continuous red
Orange flashing
Flame present prior to ignition of
the transformer
Photo cell faulty
Remedy
Check if the controller is set correctly (e.g.the temperature set at the thermostat must
be higher than the room temperature).
Have the controller replaced by the customer
service.
Check the characteristics of the electrical
system (230 V-1~ – 50 Hz).Check the functionality and position of the
selector switch. Check the fuse for soundness.
Check the supply voltage. The device willrestart automatically when the voltage value
exceeds 190 V.
Check the supply voltage. The device willrestart automatically when the voltage value
falls below 250 V.
Instruct the customer service to have the
device cleaned and fuel oil residues
removed from the combustion chamber.
Have the photo cell exchanged by the
Red flashing or
flashing that
alternates between
red and green
Motor winding interrupted or
blown
Have the motor replaced by the customer
service.
Motor bearing blocked
Motor capacitor blown
No ignition
Flame monitoring system faulty
Photo cell faulty
Have the motor replaced by the customer
service.
Have the motor capacitor replaced by the
Check the connections of the ignition cables
at the electrodes and the transformer.Check the position and the distance of the
electrodes. Check whether the electrodes are clean.Have the transformer replaced by the
Have the flame monitoring system replaced
by the customer service.
Have the photo cell exchanged by the
customer service
Burner is supplied with no or
insufficient fuel oil
Magnet valve faulty
Continuous orange
Internal error of the electronic
control unit
Fan starts and flame
burns with smoke
formation
Continuous green
• Insufficient supply of combustion
air
Excessive supply of combustion
air
• to have the coupling between the
pump and the motor checked for
soundness.• to have the fuel oil circuit checked for
intruded air and to have the lines and
filter seal checked for tightness.
to have the nozzle cleaned or
exchanged.
• to have the electrical connections
checked.• to have the safety thermostat LI
checked.
to have the magnet valve cleaned or
exchanged.
Instruct the customer service to have the
control unit reset; try at least twice. If the problem persists, have the control unit replaced.
Remove all obstacles and obstructions from
the inlet and/or outlet openings.Have the position of the adjustment ring for
the regulation of the air supply checked by
the customer service.Have the supporting disc of the burner
checked by the customer service.
Have the position of the adjustment ring for
the regulation of the air supply checked by
the customer service.
Used fuel oil contaminated or
contains water
Replace used fuel oil with clean fuel oil. Clean the fuel oil filter.
Air inside the fuel oil circuit
Insufficient fuel oil quantity at the
burner
Excessive amount of fuel oil at
the burner
Have the lines and the fuel oil filter checked
for tightness by the customer service.
• to have the pump pressure checked.
• to have the nozzle cleaned or replaced
• to have the nozzle replaced.
Device does not
switch off
Continuous green
• Sealing of the magnet valve
faulty
Have the magnet valve replaced by the
Maintenance
Maintenance and care interval
Check air inlets and outlets for dirt
and foreign objects and clean
Check air inlet grid(s) for dirt andforeign objects and clean
Clean the exterior
Visually check the inside of the
device for dirt
Check for damage
Check attachment screws
Test run
Maintenance intervals
before every
start-up
as needed
at least every
2 weeks
at least every
4 weeks
at least every
6 months
at least
annually
Maintenance and care log
Device type:
Device number
Maintenance and care interval
Check air inlets and outlets for dirt
and foreign objects and clean
Check air inlet grid(s) for dirt andforeign objects and clean
Clean the exterior
Visually check the inside of the
device for dirt
Check for damage
Check attachment screws
Test run
Comments
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature:
• Date:
Signature
Activities required before starting maintenance
Technical annex
Do not touch the mains plug with wet or damp hands.
Switch the device off.• Hold onto the mains plug while pulling the power cable out
of the mains socket. Allow the device to cool down completely.
• Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. Wipe the housing dry after cleaning.
Technical data
Parameter
Article number
Method of heating
Air flow rate
Fan
Max. nominal heat input
Nominal heat output
Value
1.430.000.128
indirect
m³/h
axial fan
34.1 kW
28.8 kW (24764 kcal)
Temperature increase ΔT
70 °C
Input voltage
Current consumption
Air transport hose connection Ø
Flue pipe connection Ø
Max. fuel consumption
V / 50 Hz
1.56 A
300 mm
150 mm
3.25 l/h
Sound level (at a distance of 1m)
75 dB (A)
Dimensions (length x width x height)
Minimum distance to walls and other
objects
A: top B: rear C: side D: front
56 kg
Weight
Fuels
The following fuels are approved for the device:• Diesel
EL fuel oil
Wiring diagram
Abbreviation
Component
Abbreviation
Component
AP
TA
ST
LI 1
EV 1
Control unit
Thermostat connection
Indicator light
Safety thermostat
Magnet valve
FO
CO
FUA
RV
Photo cell
Condenser
Fan motor
Fusing 3.15 A
Selector switch
Overview of spare parts and spare parts list IDS 30 F
Info
The position numbers of the spare parts differ from
those describing the positions of the components
mentioned in these instructions.
Cylinder head screw
(DIN 912 –M 8 x 25 VA)
Washer (DIN 125 – A Ø8.4 VA)
Self-locking hexagon nut
(DIN 985 – M 8 VA)
Washer
(DIN – Ø8.4xØ24x1.8 VA)
Self-locking hexagon nut
(DIN 985 – M 6)
Oil heater
Rivet (Ø4x10 Al)
Pipe holding fixture
Hose connection (IDS30 accessory, 300 mm adapter)
Universal connection (DN 150, conical) Rain cap (DN 150) Rivet (Ø3.2x8 V2A)
Washer (DIN – Ø6.4xØ20x1.25) 11
Bungee cord (l=450 mm) IDS 30 F frame
Hexagon socket countersunk screw
Info
The position numbers of the spare parts differ from
those describing the positions of the components
mentioned in these instructions.
Outlet cone
Flue pipe connection
Insulation plate
Combustion chamber
Top section of the body
Bottom section of the body
Support bracket body
Motor
Condenser
Support bracket engine
Power cable retainer
Cable feed-through
Air collector
Fan
Retaining clip
Air inlet grid
Flexible fuel oil hose
Clamping piece
Filter
Flexible fuel oil hose
Control box
Switchboard cover
Cable feed-through
Burner tube
Safety thermostat
Support bracket thermostat
Control box panel
Flame monitoring device
51 Mounting plate
Double-pole switch
Socket
Thermostat socket cover
Power supply cable
Lamp
Fuel oil pump
Solenoid valve coil
Solenoid valve housing
Connector, Fe
Engine / pump coupling
Connector, Fe
Fine hose
Nozzle
Nozzle holder
Supporting disc burner
Lock nut, brass
Ignition electrode
High-voltage cable
Photo cell
LDR retainer
Lock-out switch protection